Hach BioTector TOC Analyzers provide maximum uptime and reliability due to a patented self-cleaning oxidation technology that easily handles difficult samples and significantly reduces maintenance. Unlike traditional TOC analyzers, the BioTector eliminates build up issues from salts 鹽, particulates 顆粒, fats 脂肪, oils 油 and greases 重油污 that lead to drift and high maintenance.

Configurations are available for TOC, TOC/TN, and TOC/TN/TP. Please see your local Hach representative for details.

*Low Maintenance
*Superior Reliability & Low Cost of Ownership
*Intelligent Design
*High Dependability

關鍵字: 水 總有機碳連續監測, Total Bound Nitrogen, Total Phosphorous, 總氮, 總磷, 線上 總有機碳監測儀, online TOC, TN, TP analyzer, water TOC monitoring
產品介紹
With reliable, continuous monitoring and real-time process control, plant operators can optimize their processes to lower overall plant operating costs. The most advanced system in its class, BioTector products achieve precise results from the simplest to the most demanding applications.
 
With patented two-stage advanced oxidation technology, the Biotector handles even the most challenging applications involving fats, oils, greases, salts, sludge, and particulates. Oversized tubing eliminates filtration and sample contamination. There's minimal maintenance.
 
No calibration or operator intervention required between service intervals. Provides a quick pay back with cost savings in chemical dosing, waste reduction and optimized processes.
 
Low Maintenance
No calibration or service required between 6 month service intervals. Standard 6 and 12 month service kits are available.
 
Superior Reliability & Low Cost of Ownership
Typically 99.7% uptime. Provides a quick pay back with cost savings in chemical dosing, waste reduction, and optimized processes.
 
Intelligent Design
Self-cleaning technology and oversized tubing eliminates filtration. Prevents clogging and sample contamination and ensures measurement accuracy. Ability to handle up to 30% chlorides and calcium (sludge) up to 12%.
 
High Dependability
Patented Two-Stage Advanced Oxidation (TSAO) technology handles even the most challenging applications involving fats, oils, greases, salts, sludge, and particulates.
Measures clean and dirty water-analysis without filtering. Can measure particulates up to 2 mm and does not require filtering.
 
Part Number
Range
Multi-Stream
Parameter
B4QDDF052AECAE2 0 - 25 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QGDF052AECAE2 0 - 500 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QEDF052AECAE2 0 - 50 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QFDF052AECAE2 0 - 100 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QHDF052AECAE2 0 - 1000 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
B4QKDF052AECAE2 0 - 10000 mg/L C/N/P Valves for up to 3 streams with up to six 4-20 mA signals
The number of available outputs depends on the manual stream configuration.
Direct measurement of TOC, TIC, TC, TN, TP; COD, BOD via correlation; VOC via calculation
 
 
Application Notes Language Size Date Edition
Industrial Discharge Monitoring before Inlet to the Municipal WWTP
DOC043.52.30250
English UK 230 KB 2016-10 Oct16
Steinbeis decides for TOC monitoring withHach BioTector B7000i
DOC043.52.30639
English UK 697 KB 2020-09 Jul20
Steinbeis decides for TOC monitoring withHach BioTector B7000i
DOC043.53.30639
English US 710 KB 2020-09 Jul20
Brochures Language Size Date Edition
Combine the organic detection power of BioTector with the sampling ease of the Venturi Sampler.
DOC063.53.30579
English US 1 MB 2019-07 Jul19
Case Studies Language Size Date Edition
C:N:P Optimisation with TOC/TN/TP Monitoring + RTC by Hach
DOC043.52.30635
English UK 569 KB 2020-10 Jul20
C:N:P Optimization with TOC/TN/TP Monitoring + RTC by Hach
DOC043.53.30635
English US 522 KB 2020-10 Jul20
Case Study: Online TOC Monitoring with BioTector - Dow chooses an innovative oxidation technology to monitor TOC/TN online
DOC043.52.30466
English UK, English US 473 KB 2019-06 Apr19
Certificates Language Size Date Edition
BioTector Case Study: Oijen, The Netherlands
DOC043.53.30428
English US 825 KB 2018-08 Jun18
Data Sheets Language Size Date Edition
BioTector Venturi Vacuum Sampler
DOC053.53.35314
English US 343 KB 2020-09 Sep20
Hach BioTector B7000 Online TOC/TN/TP Analyzer
DOC053.53.35008
English US 863 KB 2019-02 Jan19
Engineering Tender Language Size Date Edition
B7000 TOC TN CSI Specifications
MS Word Doc
English US 46 KB 2019-02 Feb19
B7000 TOC TN drawings
Download .ZIP file and extract to your computer.
File contains transmittals in format: .dwg .dxf .pdf
English US 6 MB 2019-06  
B7000 TOC TN TP CSI Specifications
MS Word Doc
English US 48 KB 2019-02 Feb19
B7000 TOC TN TP drawings
Download .ZIP file and extract to your computer.
File contains transmittals in format: .dwg .dxf .pdf
English US 5 MB 2019-06  
 
Manuals Language Size Date Edition
Advanced Configuration Manual B7000 TOC TN TP Analyzer
DOC023.52.90672
English UK 283 KB 2020-11 Ed1
Advanced Configuration, BioTector B7000 Online TOC TN Analyzer
DOC023.52.90684
English UK 262 KB 2020-11 Ed1
Information Sheet, BioTector B7000 TOC TP Analyzer
DOC333.52.90710
English UK 107 KB 2020-11 Ed1
Installation and Operation Manual, BioTector B7000 TOC TN TP
DOC023.52.90654
English UK 8 MB 2021-06 Ed2
Installation and Operation, BioTector B7000 Online TOC TN Analyzer
DOC023.52.90653
English UK 8 MB 2021-06 Ed2
Maintenance and Troubleshooting Manual, BioTector B7000 TOC TN TP Analyzer
DOC023.52.90673
English UK 2 MB 2020-11 Ed1