Hach 公司

首頁 儀器與試劑 線上監控系統與感測器 Controllers & Sensors 溶氧/臭氧/氫 水中溶氧線上光學感測系統M1100 Orbisphere M1100 Oxygen Sensors for In-Line Applications
水中溶氧線上光學感測系統M1100 Orbisphere M1100 Oxygen Sensors for In-Line Applications
產品編號
Orbisphere M1100光學線上感測器搭配Orbisphere 410單通道控制器/Orbisphere 510多通道控制器,提供飲料生產製程新的氧氣監測方案。

M1100線上感測器提供即時的含氧量讀值,測量頻率為2秒。

M1100-L感測器可檢測極低水平至0.6 ppb - 此高度精確的儀器讀值對於控制飲料生產中的低含氧量水平極為重要,例如: 掌握啤酒廠的後發酵應用過程中的含氧量水平以確保成品之高品質。

零點校正 – 每年度的維護作業僅需幾分鐘。此過程無需化學品,在不降低測量精度的情況下,讓作業更容易,更安全。
產品介紹
Monitors oxygen in the beverage production process
The Orbisphere M1100 optical sensor, together with the Orbisphere 410 one channel and the Orbisphere 510 multi-channel controller, offers a new way of monitoring oxygen in the beverage production process.
 
Minimal Drift and Annual Calibration
The M1100 sensor provides immediate oxygen readings with a measurement frequency of two seconds. The instrument carries consistent readings with no drift for 12 months without calibration (when utilising standard weekly CIP processes), surpassing other optical sensors that display significant drift after only a few months in similar conditions.
 
Minimal Maintenance Optical Technology
The M1100 pioneered the use of luminescent technology in beverage applications, and as a result, the sensor doesn’t require the replacement of membranes or any electrolytes. Additionally, the sensor’s accuracy is unaffected by process changes or pressure shocks—further reducing maintenance. Annual maintenance is limited to just a few minutes for a zero point calibration. Chemicals are not required for this process, making the task easier and safer without reducing measurement precision.
 
Low Level Oxygen Measurement with Accurate ppb
The M1100-L sensor has a lower detection level of 0.6 ppb. This highly accurate instrument’s readings are essential to control low oxygen levels in beverage production. As an example, it is critical to control low level oxygen in the post fermentation applications of the brewery to ensure high quality of the final product.
 
High Level Oxygen Measurement with Accurate ppm
The M1100-H sensor has a range of 0-40 ppm, and is ideal for use in wort applications, for example. Even in this harsh wort environment, the instrument maintains very good accuracy and minimal drift. Only a yearly maintenance and calibration will be required in most cases.
 
機型 Part Number
Parameter
Range
Accuracy
Calibration
M1100-S00 Oxygen 0 - 2000 ppb DO (dissolved oxygen) ± 0.8 ppb or 2 % whichever is greater Single point zero calibration with standard 99.999% nitrogen (quality 50) or equivalent oxygen free gas
M1100-S10 Oxygen 0 - 2000 ppb DO (dissolved oxygen) ± 0.8 ppb or 2 % whichever is greater Single point zero calibration
M1100-S00H Oxygen 0 - 40 ppm DO (dissolved oxygen) ± 0.02 ppm or 3 % whichever is greater Two points at cap replacement (zero and air), one during use (air)
M1100-H0K Oxygen 0 - 2000 ppb DO (dissolved oxygen) ± 0.8 ppb or 2 % whichever is greater Single point zero calibration with standard 99.999% nitrogen (quality 50) or equivalent oxygen free gas
M1100-S10H Oxygen 0 - 40 ppm DO (dissolved oxygen) ± 0.02 ppm or 3 % whichever is greater Two points at cap replacement (zero and air), one during use (air)
 
 
Application Notes Type Language Size Date Edition
Application Note Part 1: Amperometric and Optical Sensors in Brewing 
DOC043.52.30246
  English UK 146 KB 2015-12 Sep 15
Application Note Part 2: Amperometric and Optical Sensors in Brewing 
DOC043.52.30306
  English UK 263 KB 2015-12 Sep 15
HOW TO MEASURE DISSOLVED OXYGEN IN THE BREWERY 
DOC040.52.10047
  English UK 338 KB 2014-07 Jul 14
Optical DO Sensors Improve Fermentation Management 
DOC043.53.30339
  English US 410 KB 2016-06 Apr16
WHERE TO MEASURE DISSOLVED OXYGEN IN THE BREWERY 
DOC040.52.10046
  English UK 216 KB 2014-07 Jul 14
WHY MEASURE DISSOLVED OXYGEN IN THE BREWERY? 
DOC040.52.10045
  English UK 258 KB 2014-07 Jul 14
Why measure Dissolved Oxygen in the brewery? 
LIT2147
  English US 138 KB 2014-07 Jul 14
Datasheets/Brochures Type Language Size Date Edition
ENGINEERING DESIGN TOOL: Mitigate Your Risk When Designing Water Analytics 
DOC063.53.30403
  English US 157 KB 2017-09 Aug17
Datasheet: Hach Orbisphere M1100 LDO Sensor 
DOC053.53.35143
  English US 1 MB 2017-11 Nov17
ENSURING WATER QUALITY For people around the world 
DOC030.53.10116
  English US 553 KB 2016-11 Sep16
Orbisphere 410 Controller 
DOC053.53.35137
  English US 504 KB 2017-12 Nov17
Orbisphere 510 Multichannel Gas and Dissolved Gas Analyzer 
DOC053.53.35142
  English US 599 KB 2017-12 Nov17
Soft Drink Oxygen Analyzer 
DOC060.53.10117
  English US 160 KB 2017-01 Sep16