水中氟離子分析儀 CA610 Fluoride Analyzer with Reagents
產品編號5740001
CA610 水中氟化物自動分析儀採用離子選擇感測器方法。
Ion-selective electrode with patented, replaceable tip. Automatic calibration. Temperature-controlled wall-jet flow cell. Rugged, lightweight enclosure. Ultra-low reagent consumption. Virtually immune to interferences. 專利技術可更換離子選擇性電極尖頭。 自動校正。 恆溫控制的流通池。 堅固輕便的外殼。試劑消耗極低。 抗干擾強,幾乎不受干擾。

典型應用 : 自來水、地面水的氟化物濃度監測

Calibration Method : 5.0 mg/L fluoride standards
Compliance Certifications : CE approved, ETL listed to UL 1262, ETL certified to CSA 22.2 No. 142
Range : 0.1 - 10.0 mg/L Fluoride
Lower Limit of Detection (LOD) : 0.10 mg/L 0.10 ppm

關鍵字 : 水 氟離子濃度 自動監測, 水 氟離子 濃度分析, 氟鹽 分析儀, 水 氟 線上監測
產品特色
Reliable, Full-time Fluoride Monitoring
The CA610 Fluoride Analyzer uses advanced ion-selective electrode (ISE) technology for continuous monitoring of fluoride concentration in drinking water effluent. Accuracy is ensured with precise control of temperature, ionic strength, and pH. Interferences that can bias measurements are virtually eliminated with this electrode.
 
Patented Electrode Design with Replaceable Tip
The proven ISE technology of the electrode is enhanced by a patented* design and manufacturing process. The lanthanum crystal at the tip of the probe is molded into a one-piece, monolithic tip that is threaded for easy removal. This prevents errors and premature failures. Electrodes are equipped with BNC connectors so that they can be independently checked with laboratory electrochemical meters.
 
Cost Effective Operation
The electrode of the CA610 analyzer is made with a molded fluoride crystal tip. The working life of the electrode is approximately one year. The specially designed tip of the electrode should be replaced every six months. Reagent consumption is very low and maintenance is simple.
 
Method of Analysis
The ISE system of the CA610 analyzer includes a reference pH electrode and a working electrode. Three reagents are used: Total Ionic Strength Adjustment Buffer (TISAB) solution and two fluoride standards. The TISAB is used for the following purposes. The Ionic strength adjustment lets the electrode respond to concentration instead of activity. The pH control ensures fluoride is present in its ionic state. The Weak complexes formed by certain metals (for example, aluminum) are broken up by TISAB and chelates potential interferents for accurate fluoride measurement.
 
Automatic Calibration
Two calibration standards are fully enclosed in the CA610 analyzer's case. The instrument performs a 2-point calibration at 0.5 and 5.0 mg/L fluoride at user-selected time intervals. Automatic calibration intervals can be set for 1 day to 1 month. Readings and calculations of the most recent calibration is stored in the instrument.