水中氧化還原電位感測器 ORP Sensor, LCP Body, Convertible, Gold Electrode Material, 5 Wire, 10-ft Cable
產品編號:2028R1
Excellent, Strong Base Chemical Compatibility
優異的強鹼化學相容性
The PPSn sensor is best suited for measuring strong base solution of more than 12 pH at elevated temperatures. It can also be sued in acidic solutions, but is not recommended when aromatic hydrocarbons are present. PPSn 感測器適用於測量 pH 值大於 12 的強鹼性溶液,尤其是在高溫條件下。亦可用於酸性溶液,但不建議在含有芳香烴的溶液中使用
LCP (Liquid Crystal Polymer), Convertible Mounting Style, 3m Analog Cable, 5-Wire with Built-In Preamplifier, Gold Electrode
Range 量測範圍 : -2000 - 2000 mV
Electrode Material : Gold
Drift : 2 mV
Flow : 3 m/s
Operating Temperature Range : -5 - 95 °C (sensor only)
Pressure Range : 10.7 bar
Temperature Sensor : NTC 300 ohm thermistor for automatic temperature compensation and analyzer temperature readout
*使用 Hach SC系列 Controllers 數位控制器進行監控
關鍵字 : online ORP analyzer, process ORP monitor, 氧化還原電位分析儀, 水中氧化還原電位 監測儀
優異的強鹼化學相容性
The PPSn sensor is best suited for measuring strong base solution of more than 12 pH at elevated temperatures. It can also be sued in acidic solutions, but is not recommended when aromatic hydrocarbons are present. PPSn 感測器適用於測量 pH 值大於 12 的強鹼性溶液,尤其是在高溫條件下。亦可用於酸性溶液,但不建議在含有芳香烴的溶液中使用
LCP (Liquid Crystal Polymer), Convertible Mounting Style, 3m Analog Cable, 5-Wire with Built-In Preamplifier, Gold Electrode
Range 量測範圍 : -2000 - 2000 mV
Electrode Material : Gold
Drift : 2 mV
Flow : 3 m/s
Operating Temperature Range : -5 - 95 °C (sensor only)
Pressure Range : 10.7 bar
Temperature Sensor : NTC 300 ohm thermistor for automatic temperature compensation and analyzer temperature readout
*使用 Hach SC系列 Controllers 數位控制器進行監控
關鍵字 : online ORP analyzer, process ORP monitor, 氧化還原電位分析儀, 水中氧化還原電位 監測儀
Exceptional Performance with the Differential Electrode Measurement Technique
This field-proven technique uses three electrodes instead of the two normally used in conventional pH sensors. Process and reference electrodes measure the pH differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
This field-proven technique uses three electrodes instead of the two normally used in conventional pH sensors. Process and reference electrodes measure the pH differentially with respect to a third ground electrode. The end result is unsurpassed measurement accuracy, reduced reference junction potential, and elimination of sensor ground loops. These sensors provide greater reliability, resulting in less downtime and maintenance.
Lower Maintenance Needs with the Replaceable Salt Bridge
The salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
The salt bridge creates a barrier to contamination which minimizes the dilution of the internal standard cell solution. The result is lower maintenance needs and a longer time period between calibrations.
Built-in Preamp or Two-Wire Transmitter
The built-in preamp produces a strong signal, enabling you to locate the analyzer up to 3000 ft. (914 m) from the sensor. An optional built-in two-wire transmitter is available for applications requiring a 4-20 mA sensor signal. This option requires that the indicating instrument of the measuring system be capable of providing 24 VDC to power the sensor, and have adjustment means to calibrate for zero offset and span.
The built-in preamp produces a strong signal, enabling you to locate the analyzer up to 3000 ft. (914 m) from the sensor. An optional built-in two-wire transmitter is available for applications requiring a 4-20 mA sensor signal. This option requires that the indicating instrument of the measuring system be capable of providing 24 VDC to power the sensor, and have adjustment means to calibrate for zero offset and span.
Versatile Mounting Styles
1.5 inch NPT threads are provided on both ends of the convertible mounting style sensor for either mounting into a pipe tee or attaching to the end of a pipe for immersion. The convertible style enables you to consolidate inventory, and thereby reduce associated costs. A union-mount style sensor and mounting tee are also available to conveniently install and remove the sensor for in-line service.
1.5 inch NPT threads are provided on both ends of the convertible mounting style sensor for either mounting into a pipe tee or attaching to the end of a pipe for immersion. The convertible style enables you to consolidate inventory, and thereby reduce associated costs. A union-mount style sensor and mounting tee are also available to conveniently install and remove the sensor for in-line service.
3,000 ft. (914 m) transmission distance
Also available with flat glass electrodes