多參數水質感測數位控制主機 sc1000系列 Multi-parameter Universal Controller Module
產品編號:
The Hach SC1000 Multi-parameter Universal Controller is a state-of-the-art modular transmitter system. The SC1000 consists of a Display Module and at least one Probe Module. Probe Modules for the SC1000 can be networked together to accommodate up to 32 digital sensors or analyzers. The SC1000 Display Module is intuitive, with an easy to use interface and large color touch-screen display that can be used for any number of parameters. One Display Module controls one or more Probe Modules connected by a digital network. The Display Module is fully portable, and can be disconnected and moved anywhere within the network. The Hach SC1000 Display Module is available with GSM/GPRS, Ethernet, and TCP/IP capability.
Prognosys is a predictive diagnostic system that allows you to be proactive in your maintenance, by alerting you to upcoming instrument issues. Know with confidence whether changes in your measurements are due to changes in your instrument or your water.
全新儀表控制平台概念 - Hach sc1000多參數通用控制器 Controller Display Module是Hach所有數位傳感器的操作平台, 最多可連接8個電極, 多台sc1000可連在一起組成網路。
Prognosys is a predictive diagnostic system that allows you to be proactive in your maintenance, by alerting you to upcoming instrument issues. Know with confidence whether changes in your measurements are due to changes in your instrument or your water.
全新儀表控制平台概念 - Hach sc1000多參數通用控制器 Controller Display Module是Hach所有數位傳感器的操作平台, 最多可連接8個電極, 多台sc1000可連在一起組成網路。
- 電極模組:單個電極模組可連接 8 個電極;多個電極模組相互聯網,可共用一個顯示模組。在電極模組裏面,也是由模擬輸出模組,數位模組等組成,功能完善,結構靈活
- 顯示模組:sc1000 顯示模組擁有彩色的觸摸螢幕、功能完備的控制器。直觀簡單的操作介面
- 即插即用:sc1000 只要將傳感器插入電極模組即可使用,無需專門設定或配置軟體
- 多種電極:Hach 的數十種類型電極都可與其相接
- 擴展輸出:要增加額外的繼電器和模擬信號輸入、輸出功能,除了在網路增加多個電極模組以外,也可以增加DIN-rail 通訊模組的方式進行
- 通訊方式:多台sc1000 控制器之間,或與連接的傳感器之間,數位信號可靠,整體性能佳
- 與外界儀器的模擬訊號通訊,數位信號通訊;數位通訊協議:MODBUS PROFIBUS
The sc1000 Display Module is intuitive, with an easy to use interface and large color touch-screen display that can be used for any number of parameters. One Display Module controls one or several Probe Modules connected by a digital network. The Display Module is fully portable, and can be disconnected and moved anywhere within the network.
The Display Module is also available with GSM/GPRS, ethernet and TCP/IP capability. Each sc1000 Probe Module provides power to the system and can accept up to 8 digital sensors/expansion boards. Probe Modules can be networked together to accommodate up to 32 digital sensors/expansion boards attached to the same network.
PROGNOSYS is a predictive diagnostic system that allows you to be proactive in your maintenance, by alerting you to upcoming instrument issues. Know with confidence whether changes in your measurements are due to changes in your instrument or your water.
Part Number
|
|||
---|---|---|---|
LXV402.99.00002 | sc1000 Multi-parameter Universal Controller Display Module (without GSM/GPRS) | Without Modbus TCP/IP | Without GSM Module |
LXV402.99.10002 | sc1000 Multi-parameter Universal Controller Display Module with Modbus TCP/IP | With Modbus TCP/IP | Without GSM Module |
LXV402.99.12002 | sc1000 Multi-parameter Universal Controller Display Module with Modbus TCP/IP and GSM/GPRS protocols (for use in USA) | With Modbus TCP/IP | With GSM (US Only) |
LXV402.99.02002 | sc1000 Multi-parameter Universal Controller Display Module with GSM/GPRS (for use in USA) | Without Modbus TCP/IP | With GSM (US Only) |
LXV402.99.11002 | sc1000 Multi-parameter Universal Controller Display Module with Modbus TCP/IP and GSM/GPRS protocols (for use outside USA) | With Modbus TCP/IP | With GSM (non-US) |
LXV402.99.01002 | sc1000 Multi-parameter Universal Controller Display Module with GSM/GPRS (for use outside USA) | Without Modbus TCP/IP | With GSM (non-US) |
In order to be able to connect sensors to the network, the sc1000 Display Module must be paired with a Probe Module
主機需搭配模組:
Part Number
|
|||||
---|---|---|---|---|---|
LXV400.99.1H072 | sc1000 Probe Module, 4 sensors, Prognosys Module, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module, Modbus 485 | No I/O Module | 4 Sensors with Conduits |
LXV400.99.1G172 | sc1000 Probe Module, 4 sensors, 4x 4-20mA Outputs, Prognosys Module, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module | One 4-20mA Output Module | 4 Sensors with Conduits |
LXV400.99.1U172 | sc1000 Probe Module, 4 sensors, 4x 4-20mA Outputs, 4 Relays, Prognosys Module, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module, 4 Relays | One 4-20mA Output Module | 4 Sensors with Conduits |
LXV400.99.1R382 | sc1000 Probe Module, 4 relays, 8mA Output, six sensors, 100-240V, no power cord | 100-240V, no power cord, with conduit | 4 Relays | Two 4-20mA Output Modules | 6 Sensors with Conduits |
LXV400.99.5B532 | sc1000 Probe Module, 6 sensors, 4mAOUT, 4mA/digitIN, 4 relays, Modbus (RS485), 100-240V, with US power cord | 100-240V, US power cord | 4 Relays, Modbus 485 | One 4-20mA Input and One 4-20mA Output | 6 Sensors |
LXV400.99.1R172 | sc1000 Probe Module, 4 sensors, 4 relays, 4x 0/4-20 Outputs, 100-240V, no power cord | 100-240V, no power cord, with conduit | 4 Relays | One 4-20mA Output Module | 4 Sensors with Conduits |
LXV400.99.1R572 | sc1000 Probe Module, 4 relays, 4mA Output, 4mA/digital input, 4 sensors, 100-240V, no power cord | 100-240V, no power cord, with conduit | 4 Relays | One 4-20mA Input and One 4-20mA Output | 4 Sensors with Conduits |
LXV400.99.10082 | sc1000 Probe Module, 6 sensors, 100-240V, no power cord | 100-240V, no power cord, with conduit | No Relay | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1A082 | sc1000 Probe Module,6 Sensors with Conduits,100-240V, no power cord, with conduit,Modbus 485,No I/O Module | 100-240V, no power cord, with conduit | Modbus 485 | No I/O Module | 6 Sensors with Conduits |
LXV400.99.10172 | sc1000 Probe Module, 4 sensors, 4x 4-20mA Outputs, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | No Relay | One 4-20mA Output Module | 4 Sensors with Conduits |
LXV400.99.10382 | sc1000 Probe Module, 6 sensors, 8mA Output, 100-240V, no power cord | 100-240V, no power cord, with conduit | No Relay | Two 4-20mA Output Modules | 6 Sensors with Conduits |
LXV400.99.1B572 | sc1000 Probe Module, 4 sensors, 4mAOUT, 4mAIN, 4 relays, Modbus (RS485) 100-240 Vac | 100-240V, no power cord, with conduit | 4 Relays, Modbus 485 | One 4-20mA Input and One 4-20mA Output | 4 Sensors with Conduits |
LXV400.99.10092 | sc1000 Probe Module, 8 sensors, 100-240V, no power cord | 100-240V, no power cord, with conduit | No Relay | No I/O Module | 8 Sensors with Conduits |
LXV400.99.1A072 | sc1000 Probe Module,4 Sensors with Conduits,100-240V, no power cord, with conduit,Modbus 485,No I/O Module | 100-240V, no power cord, with conduit | Modbus 485 | No I/O Module | 4 Sensors with Conduits |
LXV400.99.1R582 | sc1000 Probe Module, 6 sensors, 4 relays, 4mA Output, 4mA/IN, 100-240V, no power cord | 100-240V, no power cord, with conduit | 4 Relays | One 4-20mA Input and One 4-20mA Output | 6 Sensors with Conduits |
LXV400.99.10372 | sc1000 Probe Module, 4 sensors, 8x 4-20mA Outputs, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | No Relay | Two 4-20mA Output Modules | 4 Sensors with Conduits |
LXV400.99.1G092 | sc1000 Probe Module, 8 sensors, Prognosys Module, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module | No I/O Module | 8 Sensors with Conduits |
LXV400.99.10572 | sc1000 Probe Module, 4x 4-20mA Outputs and 4x 4-20mA Inputs, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | No Relay | One 4-20mA Output Module and One 4-20mA Input Module | 4 Sensors with Conduits |
LXV400.99.1B582 | sc1000 Probe Module, 6 sensors, 4x 4-20mA Outputs and 4x 4-20mA Inputs, 4 Relays, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays, Modbus 485 | One 4-20mA Output Module and One 4-20mA Input Module | 6 Sensors with Conduits |
LXV400.99.5B522 | sc1000 Probe Module, 4 sensors, 4mAOUT, 4mA/digitIN, 4 relays, Modbus (RS485), 100-240V, with US power cord | 100-240V, US power cord | 4 Relays, Modbus 485 | One 4-20mA Input and One 4-20mA Output | 4 Sensors |
LXV400.99.1G382 | sc1000 Probe Module, 6 sensors, 8x 4-20mA Outputs, Prognosys Module, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module | Two 4-20mA Output Modules | 6 Sensors with Conduits |
LXV400.99.1F572 | sc1000 Probe Module, 4 sensors, 4 relays, Profibus DP, 100-240V, no power cord | 100-240V, no power cord, with conduit | 4 Relays, Profibus DP | One 4-20mA Input and One 4-20mA Output | 4 Sensors with Conduits |
LXV400.99.5A322 | sc1000 Probe Module, 4 sensors, 8x 4-20mA Outputs, Modbus RS485, 100-240V AC, US power cord | 100-240V AC, US Power Cord | Modbus 485 | Two 4-20mA Output Modules | 4 Sensors |
LXV400.99.1E082 | sc1000 Probe Module, 6 sensors, Profibus DP, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Profibus DP | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1R682 | sc1000 Probe Module, 6 sensors, 8x 4-20mA Outputs and 4x 4-20mA Inputs, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays | Two 4-20mA Output Modules and One 4-20mA Input Module | 6 Sensors with Conduits |
LXV400.99.1H082 | sc1000 Probe Module, 6 sensors, Prognosys Module, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module, Modbus 485 | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1E072 | sc1000 Probe Module, 4 Sensors, Profibus DP, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Profibus DP | No I/O Module | 4 Sensors with Conduits |
LXV400.99.1G082 | sc1000 Probe Module, 6 sensors, Prognosys Module, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1R282 | sc1000 Probe Module, 6 sensors, 4x 4-20mA Input Module, 4 Relays, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays | One 4-20mA Input Module | 6 Sensors with Conduits |
LXV400.99.1B082 | sc1000 Probe Module, 6 sensors, 4 Relays, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays, Modbus 485 | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1U582 | sc1000 Probe Module, 6 sensors with conduits, 4x 4-20mA Outputs and 4x 4-20mA Inputs, Prognosys Module, 4x Relays, 100-240V AC, US power cord | 100-240V, no power cord, with conduit | Prognosys Module, 4 Relays | One 4-20mA Input and One 4-20mA Output | 6 Sensors with Conduits |
LXV400.99.1B482 | sc1000 Probe Module, 6 sensors, 8x 4-20mA Input Modules, 4 Relays, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays, Modbus 485 | Two 4-20mA Input Modules | 6 Sensors with Conduits |
LXV400.99.5R622 | sc1000 Probe Module, 4 sensors, 8x 4-20mA Outputs and 4x 4-20mA Inputs, 4 Relays, 100-240V AC, US Power Cord | 100-240V AC, US Power Cord | 4 Relays | Two 4-20mA Output Modules and One 4-20mA Input Module | 4 Sensors |
LXV400.99.1B282 | sc1000 Probe Module, 6 sensors, 4x 4-20mA Inputs, 4 Relays, Modbus RS485, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays, Modbus 485 | One 4-20mA Input Module | 6 Sensors with Conduits |
LXV400.99.1R082 | sc1000 Probe Module, 6 sensors, 4 Relays, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | 4 Relays | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1S082 | sc1000 Probe Module, 6 sensors with conduits, Prognosys Module, Profibus DP, 100-240V AC, US power cord | 100-240V, no power cord, with conduit | Prognosys Module, Profibus DP | No I/O Module | 6 Sensors with Conduits |
LXV400.99.1U382 | sc1000 Probe Module, 6 sensors with conduits, 8x 4-20mA Outputs, Prognosys Module, 4x Relays, 100-240V AC, no power cord | 100-240V, no power cord, with conduit | Prognosys Module, 4 Relays | Two 4-20mA Output Modules | 6 Sensors with Conduits |
LXV400.99.1U572 | sc1000 Probe Module, 4 sensors with conduits, 4x 4-20mA Outputs and 4x 4-20mA Inputs, Prognosys Module, 4x Relays, 100-240V AC, US power cord | 100-240V, no power cord, with conduit | Prognosys Module, 4 Relays | One 4-20mA Input and One 4-20mA Output | 4 Sensors with Conduits |