水中餘氯線上分析儀(pH感測器) CLF10 sc Free Chlorine Analyzer (Panel Only) with pHD Differential Sensor
產品編號LXV45A.99.13022
Hach's answer to reagentless amperometric chlorine measurement. CL10 sc使用電流分析儀測量餘氯或總氯,不需使用試劑,因而無需更換常規試劑和額外廢物料管理。

CLT10 sc / CLF10 sc: Total and free reagentless chlorine sensors

The CLF10 sc Free Chlorine Analyzer measures free chlorine continuously for real time process control. It is based on amperometric technology and is fully compatible with all of Hach's digital controllers. The CLF10 sc can be used in most municipal and industrial applications and is best utilized where waste stream management is a constraint. This analyzer is equipped with a pH sensor for use with the unique Cal Watch advanced diagnostic feature.

Measurement Method 測試方法 : Reagentless, electrochemical, three-electrode amperometric system
Range : 0 - 20 ppm Cl₂
Controller Compatibility : sc controller platform 使用 Hach SC系列 digital controllers 水質數位控制主機進行監控

關鍵字 : 水 餘氯線上監測, 總氯線上監測, 氯濃度連續監測, 氯連續監測儀, 氯離子 線上檢測儀, 水 氯離子 監控
產品介紹

Exclusive Self Diagnostics
The CLF10 sc and CLT10 sc analyzers leverage Hach's exclusive self diagnostics to alert users when the process has changed or the instrument needs servicing. Diagnostic features include the Cal Watch algorithm for warning of pH and chlorine calibration deviation and a non-contacting flow sensor for notification of insufficient sample flow.

 
No Reagent Replacement, No Waste Stream
Chlorine measurement with an amperometric analyzer, such as the CLF10 sc or CLT10 sc, does not require reagents, eliminating the need for routine reagent replacement and waste stream management.
 
Real-Time Process Control
The CLF10 sc and CLT10 sc analyzers allow for real-time control of disinfection processes by providing continuous readings that indicate when treatment conditions have changed.

 

Compatible with Hach's "Plug and Play" Digital Controllers
The CLF10 sc and CLT10 sc analyzers can be used with any Hach sc digital controller. Whether you're measuring turbidity or chlorine, you only need to learn one controller for all your water analysis measurement points. Hach sc controllers have no complicated wiring or setup procedures. Just plug in any Hach digital sensor and it's ready to use without software configuration.
 
EPA Compliant According to Method 334.0
In accordance with EPA Method 334.0, the CLF10 sc and CLT10 sc analyzers can be used for reporting chlorine residual measurements. Additionally, Hach has created a suite of laboratory products and methods to help with startup and quality control procedures required in Method 334.0.  
CLF10 sc 和 CLT10 sc 氯分析儀符合美國EPA 方法 334.0 (飲用水檢測標準)

 

Extended up-time via various service options
The Hach ISO certified service is available close to you. It offers a range from one-off installation service to warranty extension up to 5 years. Thus, the lifetime of the system is increased and costs become transparent and foreseeable.