水中導電度/總溶解固體物分析儀(實驗室水質分析主機搭配電極) HQ430D Laboratory Conductivity/TDS Meter Package with 4 Poles Graphite CDC401 Cell
產品編號:8509600
HQD測試主機連接智慧型Intellical電極,可自動識別測試參數,校正歷史記錄和測試方法設定,大幅減少人為操作錯誤和耗費於設定程序的時間。智慧型數位 CDC401導電度分析電極適合測量廢污水、飲用水或一般水質的導電度、鹽度、電阻率或總溶解固體 (TDS)。
Designed for water quality experts, the Hach HQ430D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart Intellical electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate.
The Intellical CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications.
Method 測試方法 : 8160 Direct Measurement Method
Range 量測範圍 : 0.01 - 200,000 µS/cm
關鍵字 : 水 導電度計, 水 導電度檢測儀, 水中 導電度檢測計, 水 TDS 總溶解 固體物 測定計, 導電度分析儀, 實驗室 conductivity meter, 水中 懸浮固體 濃度 分析儀
Designed for water quality experts, the Hach HQ430D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart Intellical electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate.
The Intellical CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications.
Method 測試方法 : 8160 Direct Measurement Method
Range 量測範圍 : 0.01 - 200,000 µS/cm
關鍵字 : 水 導電度計, 水 導電度檢測儀, 水中 導電度檢測計, 水 TDS 總溶解 固體物 測定計, 導電度分析儀, 實驗室 conductivity meter, 水中 懸浮固體 濃度 分析儀
Conductivity | Method | Range | Reagent Set(s) | USEPA Compliant? |
---|---|---|---|---|
8160 Direct Measurement Method | 0.01 - 200,000 µS/cm | View | Y |
Flexible Laboratory bench Conductivity/TDS Meter for efficient water quality parameters testing
Single input channel for flexible measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx), Temperature, Ion Selective Electrode (ISE) direct concentration reading for Ammonia, Ammonium, Fluoride, Chloride, Sodium - connect any
Intellical™ smart probe.
Intuitive user interface for simple operation, reliable and accurate results
Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.
Trust your measurements - Intellical™ smart probes store all calibrations in the probe
Calibration history allows quick and easy change out of probes without re-calibrating. The HQD™ smart system records serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log for complete Good Laboratory Practice (GLP) traceability..
Enhance data connectivity with easy to read results
Internal USB ports simplify data transfer, peripherals, and software updates and connection to PCs printer and keyboards, with a large ultra-bright backlit LCD screen with large font size for convenient reading.
Complete convenient kit
Package content includes everything you need to start testing. Details below
Application Notes | Language | Size | Date | Edition |
---|---|---|---|---|
Calibration of the High Purity 8362sc pH Electrode DOC040.53.10101 |
English US | 199 KB | 2017-11 | Nov17 |
Electrochemistry Theory and Practice DOC182.53.90629 |
English US | 3 MB | 2018-12 | Dec18 Ed3 |
Measure pH, conductivity, oxygen with HQD DOC042.53.20010 |
English US | 446 KB | 2016-01 | Jan16 |
Measuring Scale Forming Potential in Cooling Water DOC042.53.20252 |
English US | 531 KB | 2016-10 | Oct16 |
Technical note pH measurement system DOC42.52.20152 |
English UK | 183 KB | 2013-11 | |
Technical Note pH Trace Analysis (en) DOC042.52.20150 |
English UK | 95 KB | 2013-11 |
Brochures | Language | Size | Date | Edition |
---|---|---|---|---|
Complete Water Analysis Solutions for POWER GENERATION DOC030.53.10024 |
English US | 3 MB | 2020-06 | Feb20 |
Complete Water Analysis Solutions for Power, Heat & Steam Generation DOC030.52.10024 |
English UK | 964 KB | 2018-12 | Oct18 |
Complete Water and Product Quality Analysis<br />Beverage Industry DOC030.53.10021 |
English US | 1 MB | 2020-12 | Aug20 |
The best solution for accurate results in all applications - HQD meters and high performance pH electrodes DOC032.53.20163 |
English US | 328 KB | 2015-08 | Aug15 |
Guides | Language | Size | Date | Edition |
---|---|---|---|---|
GSA Supply Schedule | English US | 100 KB | 2016-11 | |
HQD Digital Meters and Intellical™ Probes Data Sheet LIT2599 |
English US | 809 KB | 2017-11 | Rev9 |
Measuring Chloride in Power Applications DOC040.53.10132 |
English US | 707 KB | 2018-02 | Jan18 |
Methods/Procedures | Language | Size | Date | Edition |
---|---|---|---|---|
Conductivity, Direct Measurement Method 8160, Conductivity Meter DOC316.53.01199 |
English US | 136 KB | 2021-02 | Ed 10 |