水中氟離子選擇電極與試劑組 IntelliCAL ISEF12101 Fluoride (F⁻) Ion Selective Electrode (ISE) with Calibration Reagents Pack
產品編號ISEF121AP
The IntelliCALⓇ Fluoride ISE Analysis Package contains all you need to start measuring fluoride (F-) with your HQD meter instrument: The IntelliCALⓇ ISEF121 Fluoride ISE with 1 m cable, 500 mL bottles of 0,5 mg/L, 1 mg/L and 2 mg/L of Hach Fluoride standard solutions, pack of 100 Hach fluoride ionic strength adjustor (ISA) Powder Pillows.
IntelliCALⓇ 氟化物 ISE 分析組包括測量氟離子 (F-)濃度 所需:IntelliCALⓇ ISEF121 氟離子 ISE 電極(1 公尺電纜)、500 ml瓶裝的 0.5 mg/L、1 mg/L 和 2 mg/L 100 ml瓶裝的 0.5 mg/L、1 mg/L 和 2 mg/L 氟離子強度調節劑 (ISA) 粉枕包試劑。

Parameter 分析參數 : Fluoride

Range 量測範圍 : 0.01 mg/L (5 x 10-7 M) - 19 g/L (1 M) F⁻

Accuracy 準確度 : ±0.02 mV or 0.05%, whichever is greater

Reference Type : Ag/AgCl

Resolution : Selectable up to 4 significant digits

Electrode Type : Non-Refillable Dritek Gel Reference Element

ISA Required : Fluoride ISA
(#258999)

Sensor Type : Solid-state crystal membrane

Special Features : Dry storage & fast response time. No replacement membranes.

Thermistor : ATC
Temperature Range : 5 - 50 °C (41 - 122 °F)
Temperature Accuracy : ±0.3 °C (±0.54 °F)
Temperature Resolution : 0.1 °C (0.18 °F)

Test requirements : Parameter Needed: Fluoride
Minimum Sample Depth (mm): 26

*使用 Hach HQD系列 meter 智慧型數位水質主機進行分析

What's included : Kit includes IntelliCAL ISEF121 combination fluoride ISE, 1m cable (no. ISEF12101), Hach fluoride standard solutions: 500 mL bottles of 0,5 mg/L (no.40505), 1.0 mg/L (no.29149) and 2.0 mg/L (no.40520), a pack of 100 Hach fluoride ionic strength adjustor (ISA) Powder Pillows (no. 258999), and ISE Basic User Manual.

關鍵字 : 數位型 水中 氟離子 分析 探頭 probe, 廢污水 氟離子 濃度 檢測 電極, 廢污水 氟離子 分析, 水中 氟 ISE 分析儀, 水中氟鹽, fluoride analysis
產品介紹
Requires virtually no maintenance
The solid-state sensor design allows for DRY storage of the ISE without a shelf life. Also, the probe does not require the electrolyte to be refilled or membrane replacement.
 
Fast, stable, and accurate results
IntelliCAL digital probes lock on the result when the measurement is stable, removing the guesswork in having a moving number. Additionally, the probe’s large annular reference junction provides maximum surface area between sample and reference electrolyte for fast measurement stability.
 
Ultimate traceability in measurement history
Stored time and date stamp for each measurement, operator and sample ID, calibration history, parameter, and probe serial number
 
Can be moved between meters without the need to re-calibrate or re-enter measurement settings
Ideal for a multi-user environment with multiple HQD series Laboratory and Portable meters