水中非離子界面活性劑試劑 Nonionic Surfactants TNTplus Vial Test, LR (0.2 - 6.0 mg/L as Triton X-100)
產品編號:TNT875
Expert Low Range Nonionic Surfactants test made simple.
專業精確分析水中低濃度非離子界面活性劑測試
Nonionic Surfactants TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For determination of lower concentrations of Nonionic Surfactants by the TBPE method, calibrated with Triton X-100.
適用於採用 TBPE 法測定水中低濃度非離子界面活性劑,並經 Triton X-100 校正。傳統的界面活性劑(表面活性劑)的檢測通常牽涉耗時的處理步驟,需要昂貴的高端儀器或使用大量有毒化學品。 而使用HACH TNTplus界面活性劑預製檢測試劑,您只需將水樣和包含的試劑添加到樣品瓶中,搖動樣品瓶於一段規定的時間後並透過HACH分光光度計自動分析!
The Direct Read Technology will provide your Surfactants results in mg/L! No more cleaning glassware, dealing with large amounts of toxic waste, and worrying about human errors.
直接讀取技術以毫克/公升為單位提供表面活性劑分析數據!無需再清洗玻璃器皿、處理大量有毒廢棄物,也無需擔心人為錯誤。
Upgrade from traditional Surfactants methods to TNTplus Surfactants reagents today! 現在就從傳統界面活性劑方法轉換升級到 TNTplus 界面活性劑試劑
Method Name : TBPE
Method Number : 10275
Parameter : Surfactants, Nonionic
Platform : TNT plus™
Range : 0.2 - 6.0 mg/L as Triton x 100
*使用分光光度計 DR3900, DR6000, DR1900, DR2800, DR3800, DR5000系列進行分析
關鍵字 : 水中 非離子界面活性劑 測定 試劑, 水中 非離子界面活性劑 濃度 分析, waster Nonionic Surfactants analysis, 水中 界面活性劑 分析 試劑
專業精確分析水中低濃度非離子界面活性劑測試
Nonionic Surfactants TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For determination of lower concentrations of Nonionic Surfactants by the TBPE method, calibrated with Triton X-100.
適用於採用 TBPE 法測定水中低濃度非離子界面活性劑,並經 Triton X-100 校正。傳統的界面活性劑(表面活性劑)的檢測通常牽涉耗時的處理步驟,需要昂貴的高端儀器或使用大量有毒化學品。 而使用HACH TNTplus界面活性劑預製檢測試劑,您只需將水樣和包含的試劑添加到樣品瓶中,搖動樣品瓶於一段規定的時間後並透過HACH分光光度計自動分析!
The Direct Read Technology will provide your Surfactants results in mg/L! No more cleaning glassware, dealing with large amounts of toxic waste, and worrying about human errors.
直接讀取技術以毫克/公升為單位提供表面活性劑分析數據!無需再清洗玻璃器皿、處理大量有毒廢棄物,也無需擔心人為錯誤。
Upgrade from traditional Surfactants methods to TNTplus Surfactants reagents today! 現在就從傳統界面活性劑方法轉換升級到 TNTplus 界面活性劑試劑
Method Name : TBPE
Method Number : 10275
Parameter : Surfactants, Nonionic
Platform : TNT plus™
Range : 0.2 - 6.0 mg/L as Triton x 100
*使用分光光度計 DR3900, DR6000, DR1900, DR2800, DR3800, DR5000系列進行分析
關鍵字 : 水中 非離子界面活性劑 測定 試劑, 水中 非離子界面活性劑 濃度 分析, waster Nonionic Surfactants analysis, 水中 界面活性劑 分析 試劑
Easy and safe handling
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
No reagent blank necessary
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
Automatic method detection
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
Documented shelf life and COA
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Certificate of Analysis (COA) is available on RFID tag on the box.