實驗室水中導電度計/總溶解固體計 HQ430D Lab Conductivity/TDS Meter Package with 4 Poles Graphite CDC401 Cell
產品編號:8509600
HQD測試主機連接智慧型Intellical電極,可自動識別測試參數,校正歷史記錄和測試方法設定,大幅減少人為操作錯誤和耗費於設定程序的時間。智慧型數位 CDC401導電度分析電極適合測量廢污水、飲用水或一般水質的導電度、鹽度、電阻率或總溶解固體 (TDS)。
Designed for water quality experts, the Hach HQ430D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart Intellical electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate.
The Intellical CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications.
Model : HQ430D – Multi/1 Channel
Compliance Certifications : CE.WEEE
Method 測試方法 : 8160 Direct Measurement Method
Sensors 分析電極 : Sensor A: CDC40101
Sensor B: NA
Sensor C: NA
Range 量測範圍 :
Conductivity: 0.0 µS/cm - 200 mS/cm
TDS: 0.00 mg/L - 50.0 g/L as NaCl
Salinity: 0 - 42 ppt or ‰
Resistivity: 2.5 Ωcm - 49 MΩcm
Accuracy :
Cond: ±0.5% of reading | TDS: ±0.5% ±1 digit | Salinity: ±0.1, ±1 digit
Calibration 校正 : Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder : Off, selectable from 2 hours to 7 days
Data Storage 數據儲存 : Automatic, GLP ISO compliant reading data stored with calibration details.
Data Memory 數據記憶量 : 500 records/FIFO
Data Export 數據輸出 : Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Display 顯示 : Detailed mode/Large mode
Display Type : 440 x 160 pixel LCD with backlight illumination
GLP Features : Date; Time; Sample ID; Operator ID
IP Rating 防護等級 : IP54 (Resistant to spray of water; Dust-proof)
Automatic Buffer Recognition 自動識別緩衝 : Yes
Communication 通訊 : Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC)
What's included : Meter package includes HQ430D Laboratory Multi Meter, Universal electrode Stand with electrode holder, CDC401 conductivity/TDS/salinity cell with 1 m cable, NaCl conductivity standard (1000 µS/cm, 491 mg/L, 100 mL), 4 Alkaline 1,5V AA batteries, Power Supply Adapter, Power Cord, USB cable for data transfer, and Operating Documentation.
關鍵字 : 水 導電度計, 水 導電度檢測儀, 測定水中導電度濃度, 水 總溶解固體計, 導電度分析儀, 實驗室 conductivity meter, conductivity probe, TDS meter, TDS probe, 水中鹽度, 水中電阻率, salinity analysis, Resistivity analysis
Designed for water quality experts, the Hach HQ430D Laboratory Multi-Meter is an advanced laboratory meter that takes the guesswork out of measurements. HQD meters connect with smart Intellical electrodes that automatically recognize the testing parameter, calibration history, and method settings to minimize errors and setup time. The advanced HQD Laboratory Meter is designed to withstand years of continuous lab use. HQD meters feature a simple user interface that does not require manuals or training to operate.
The Intellical CDC401 with 1 m cable CDC401 is a digital, graphite, 4-pole conductivity electrode, ideal for measuring electrical conductivity, salinity, resistivity, or total dissolved solids (TDS) in wastewater, drinking water, or general water quality applications.
Model : HQ430D – Multi/1 Channel
Compliance Certifications : CE.WEEE
Method 測試方法 : 8160 Direct Measurement Method
Sensors 分析電極 : Sensor A: CDC40101
Sensor B: NA
Sensor C: NA
Range 量測範圍 :
Conductivity: 0.0 µS/cm - 200 mS/cm
TDS: 0.00 mg/L - 50.0 g/L as NaCl
Salinity: 0 - 42 ppt or ‰
Resistivity: 2.5 Ωcm - 49 MΩcm
Accuracy :
Cond: ±0.5% of reading | TDS: ±0.5% ±1 digit | Salinity: ±0.1, ±1 digit
Calibration 校正 : Demal (1D/ 0.1D/ 0.01D);
Molar (0.1M/ 0.01M/0.001M);
NaCl (0.05%; 25µS/cm; 1000µS/cm; 18mS/cm);
Standard sea water;
User defined
Calibration Intervals/Alerts/Reminder : Off, selectable from 2 hours to 7 days
Data Storage 數據儲存 : Automatic, GLP ISO compliant reading data stored with calibration details.
Data Memory 數據記憶量 : 500 records/FIFO
Data Export 數據輸出 : Download via USB connection to PC or flash memory device. Automatically transfer entire data log or as readings are taken.
Display 顯示 : Detailed mode/Large mode
Display Type : 440 x 160 pixel LCD with backlight illumination
GLP Features : Date; Time; Sample ID; Operator ID
IP Rating 防護等級 : IP54 (Resistant to spray of water; Dust-proof)
Automatic Buffer Recognition 自動識別緩衝 : Yes
Communication 通訊 : Integrated USB type A (for USB 2.0 flash memory device, printer, keyboard) and Integrated USB type B (for PC)
What's included : Meter package includes HQ430D Laboratory Multi Meter, Universal electrode Stand with electrode holder, CDC401 conductivity/TDS/salinity cell with 1 m cable, NaCl conductivity standard (1000 µS/cm, 491 mg/L, 100 mL), 4 Alkaline 1,5V AA batteries, Power Supply Adapter, Power Cord, USB cable for data transfer, and Operating Documentation.
關鍵字 : 水 導電度計, 水 導電度檢測儀, 測定水中導電度濃度, 水 總溶解固體計, 導電度分析儀, 實驗室 conductivity meter, conductivity probe, TDS meter, TDS probe, 水中鹽度, 水中電阻率, salinity analysis, Resistivity analysis
Flexible Laboratory bench Conductivity/TDS Meter for efficient water quality parameters testing
Single input channel for flexible measurement of pH, Conductivity, Total Dissolved Solid (TDS), Optical Dissolved Oxygen (DO), Biochemical Oxygen Demand (BOD), Oxydo Reduction Potential (ORP/RedOx), Temperature, Ion Selective Electrode (ISE) direct concentration reading for Ammonia, Ammonium, Fluoride, Chloride, Sodium - connect any
Intellical™ smart probe.
Intuitive user interface for simple operation, reliable and accurate results
Guided calibration and check standard routines reduce calibration errors while stabilization alerts and visual measurement lock ensure that you can trust the accuracy of the results.
Trust your measurements - Intellical™ smart probes store all calibrations in the probe
Calibration history allows quick and easy change out of probes without re-calibrating. The HQD™ smart system records serial numbers, current calibration data, user ID, sample ID, time, and date automatically in the data log for complete Good Laboratory Practice (GLP) traceability..
Enhance data connectivity with easy to read results
Internal USB ports simplify data transfer, peripherals, and software updates and connection to PCs printer and keyboards, with a large ultra-bright backlit LCD screen with large font size for convenient reading.
Complete convenient kit
Package content includes everything you need to start testing. Details below