水中氨, 一氯胺線上分析儀 5500sc Ammonia Monochloramine Analyzer, 1 Channel with External Filter
產品編號:5500.AMC.3.KTO
The 5500sc Ammonia Monochloramine Analyzer provides all the information you need to eliminate nitrification events and taste and odor issues, giving you total confidence in your process.
Hach 氨, 一氯胺分析儀 5500sc 提供您所需的監測數據,協助您消除硝化反應以及異味問題,讓您充分掌握處理過程狀況。
Chloramination made easy.
Certifications 認證 :
CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000
cETLus (UL 61010-1:2012; NEMA 250:2003; CSA C22.2 No 61010-1:2012)
Australian RCM Marking
Parameter 分析參數 : Total Ammonia, Monochloramine, and Free Ammonia 總氨、一氯胺和遊離氨
Light Source 光源 : Class 1M LED (light emitting diode) with a peak wavelength of 650 nm
Range 量測範圍 :
0.01 - 2 ppm (as N),
0.1 - 10.0 mg/L (as Cl₂)
Accuracy : ± 5 % or 0.01 ppm (as N) for sample temperature 5 - 40 °C (41 - 104 °F); ±10% or 0.02 ppm for sample temperature 40 - 50 °C (104 - 122 °F), whichever is greater
Lower Limit of Detection (LOD) : 0.01 ppm (as N)
Repeatability : 3 % or 0.01 ppm (as N), whichever is greater
Response Time : Within 5 minutes
Sample Flow Rate : 100 - 1000 mL/min
Cycle Time : 4.5 min minutes
Grab Sample : Grab Sample In and Grab Sample Out capability
Communication 通訊介面 : Modbus RS485, Profibus DP (available with external controller), 4-20mA Output
Enclosure Rating : IP56 / NEMA 4X
關鍵字 : 總氨 監測, 游離氨 監測, 一氯胺 監測
Hach 氨, 一氯胺分析儀 5500sc 提供您所需的監測數據,協助您消除硝化反應以及異味問題,讓您充分掌握處理過程狀況。
Chloramination made easy.
Certifications 認證 :
CE (EN 61326-1: 2006; EN 61010-1: 2010; EN 60529: 1991, +A1:2000
cETLus (UL 61010-1:2012; NEMA 250:2003; CSA C22.2 No 61010-1:2012)
Australian RCM Marking
Parameter 分析參數 : Total Ammonia, Monochloramine, and Free Ammonia 總氨、一氯胺和遊離氨
Light Source 光源 : Class 1M LED (light emitting diode) with a peak wavelength of 650 nm
Range 量測範圍 :
0.01 - 2 ppm (as N),
0.1 - 10.0 mg/L (as Cl₂)
Accuracy : ± 5 % or 0.01 ppm (as N) for sample temperature 5 - 40 °C (41 - 104 °F); ±10% or 0.02 ppm for sample temperature 40 - 50 °C (104 - 122 °F), whichever is greater
Lower Limit of Detection (LOD) : 0.01 ppm (as N)
Repeatability : 3 % or 0.01 ppm (as N), whichever is greater
Response Time : Within 5 minutes
Sample Flow Rate : 100 - 1000 mL/min
Cycle Time : 4.5 min minutes
Grab Sample : Grab Sample In and Grab Sample Out capability
Communication 通訊介面 : Modbus RS485, Profibus DP (available with external controller), 4-20mA Output
Enclosure Rating : IP56 / NEMA 4X
關鍵字 : 總氨 監測, 游離氨 監測, 一氯胺 監測
Easy operation
The analyzer offers an easy-to-operate, low-maintenance solution to help you maintain the proper chlorine to ammonia ratio and assure there is no free ammonia in your system that could lead to nitrification. We removed the traditional pumps associated with reagent delivery and replaced them with a pressurized system to eliminate the hassles and maintenance that pumps can cause.
Reliability without all the work
With Prognosys, the analyzer’s onboard predictive diagnostic software, you will have early insight into the measurement reliability and service requirements of your instruments. A user-friendly interface, color coded reagent bottles and at-a-glance status lights will offer peace of mind the instrument is up and running.
With Prognosys, the analyzer’s onboard predictive diagnostic software, you will have early insight into the measurement reliability and service requirements of your instruments. A user-friendly interface, color coded reagent bottles and at-a-glance status lights will offer peace of mind the instrument is up and running.
The 5500sc Ammonia Monochloramine Analyzer provides continuous monitoring, so you can trust that your instrument is giving you the information you need to control your chloramination process.