(高濃度)鹽水/海水化學需氧量試劑 COD in salt-/seawater - TNTplus Vial Test, HR (70 - 1000 mg/L COD)
產品編號:TNT816
Expert COD test made simple. 輕鬆完成專業的水質COD分析
For saline COD samples with Chloride concentrations up to 20,000 mg/L Cl-!
適用於氯化物濃度高達 20,000 mg/L Cl- 的鹽水 COD 水樣
COD TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For photometric determination of high range COD by the reactor digestion method.
使用精心設計的Hach 分光光度計搭配COD TNTplus® 化學試劑,可簡化水質分析,每次分析都獲得準確結果。以加熱反應消解法分析水中低濃度化學需氧量。
High Chloride concentrations usually interfere COD testing and lead to a high bias. Diluting samples to reduce the Chloride concentration may lead to high variability in COD results. TNT816 is a safe, reliable and very easy to use method for the photometric detection of COD in saltwater samples, e.g. industrial wastewater. The Direct Read Technology will provide your COD result to the nearest mg/L! No more sample dilutions, cleaning glassware and dealing with large amounts of hazardous reagents and waste.
高濃度氯化物通常會干擾 COD 測試並導致較大的偏差。低濃度 COD 水樣不能簡單地稀釋,因為 COD 的偵測限值很關鍵。 TNT816 安全可靠且容易使用的光度法分析含鹽水樣的化學需氧量濃度,例如 工業廢水。直讀技術可將 COD 分析數據精確到 mg/L!無需再清洗玻璃器皿,也無需處理危險試劑和廢棄物
25 COD vials per box.
搭配Hach 分光光度計使用 Instrument : DR3900, DR6000, DR1900
測試方法 Method Name : Reactor Digestion
測試參數 Parameter : COD (for samples up to 20000 mg/L Chloride)
Range 量測範圍 : 70 - 1000 mg/L COD
關鍵字 : 海水 含鹽水 高濃度 COD 分析 試劑, salt water COD, seawater COD,
For saline COD samples with Chloride concentrations up to 20,000 mg/L Cl-!
適用於氯化物濃度高達 20,000 mg/L Cl- 的鹽水 COD 水樣
COD TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. For photometric determination of high range COD by the reactor digestion method.
使用精心設計的Hach 分光光度計搭配COD TNTplus® 化學試劑,可簡化水質分析,每次分析都獲得準確結果。以加熱反應消解法分析水中低濃度化學需氧量。
High Chloride concentrations usually interfere COD testing and lead to a high bias. Diluting samples to reduce the Chloride concentration may lead to high variability in COD results. TNT816 is a safe, reliable and very easy to use method for the photometric detection of COD in saltwater samples, e.g. industrial wastewater. The Direct Read Technology will provide your COD result to the nearest mg/L! No more sample dilutions, cleaning glassware and dealing with large amounts of hazardous reagents and waste.
高濃度氯化物通常會干擾 COD 測試並導致較大的偏差。低濃度 COD 水樣不能簡單地稀釋,因為 COD 的偵測限值很關鍵。 TNT816 安全可靠且容易使用的光度法分析含鹽水樣的化學需氧量濃度,例如 工業廢水。直讀技術可將 COD 分析數據精確到 mg/L!無需再清洗玻璃器皿,也無需處理危險試劑和廢棄物
25 COD vials per box.
搭配Hach 分光光度計使用 Instrument : DR3900, DR6000, DR1900
測試方法 Method Name : Reactor Digestion
測試參數 Parameter : COD (for samples up to 20000 mg/L Chloride)
Range 量測範圍 : 70 - 1000 mg/L COD
關鍵字 : 海水 含鹽水 高濃度 COD 分析 試劑, salt water COD, seawater COD,
Easy and safe handling
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk.
No reagent blank necessary
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
The high quality of TNTplus vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money!
Automatic method detection
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware.
Documented shelf life and COA
The 2D vial barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.
The 2D vial barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box.