水中二氧化氯分析儀 9187sc Chlorine Dioxide Amperometric Sensor
產品編號:LXV434.99.00001
Smart amperometric Chlorine Dioxide Analyzer: 9187sc 智慧型安培法(電流法)連續監測水中二氧化氯
The 9187 sc Chlorine Dioxide (ClO2) Sensor is an online, single-channel industrial sensor that measures ClO2 in drinking water treatment plants, distribution networks, and other applications that require monitoring ClO2 at the ppb and ppm levels. This instrument uses an amperometric method to measure ClO2 concentration. A membrane allows the selective diffusion of ClO2 molecules to the amperometric sensor. The measurement is compensated for temperature.
Hach 9187 sc 二氧化氯感測器採用安培法(電流法)測量 ClO2 濃度。連續監測飲用水處理廠、配水系統、以及其他需要監測 ppb 和 ppm 等級的水中二氧化氯濃度。量測結果經過溫度補償。
- Selective Membrane Avoids Interference from other species
- Easy Setup and Maintenance 設定簡單, 維護容易
- Compatible with Hach's "Plug and Play" Digital Controllers 與Hach SC系列水質數位控制主機相容
Parameter 分析參數 : Chlorine Dioxide
Measuring Principle 量測方法 : Amperometric/Membrane (electrode, membrane, electrolyte) 安培/膜式(電極、膜、電解質)
Range 量測範圍 : 0 - 2 mg/L ClO2
Accuracy : 5% or ±10 ppb ClO2, whichever is greater
Lower Limit of Detection (LOD) : 0.01 mg/L ClO2
Measuring Interval : Continuous 連續監測
Response Time 反應時間 : 90% in less than 90 seconds
Sample Input : 0.25 " outer diameter
Sample Output : 0.5 " inner diameter
Flow : 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell
Temperature Compensation 溫度補償 : Automatic over sample temperature range
Calibration Method 校正 :
Zero Calibration: Electrically or with ozone-free water
Calibration: Comparison of lab method with process sample
Calibration Interval : 2 months
Maintenance Interval : 6 months for membrane and electrolyte (measurement cell)
Enclosure Rating : IP66 / NEMA 4X
What's included : Hach 9187sc Chlorine Dioxide sensor panel, 4 spare membranes, and Manual.
關鍵字 : 水中二氧化氯 監測儀, 水 二氧化氯 自動分析儀, 水 二氧化氯 感測器, 水 二氧化氯 sensor, ClO2 monitoring, Chlorine Dioxide 線上監測, 二氧化氯 online analyzer
The 9187 sc Chlorine Dioxide (ClO2) Sensor is an online, single-channel industrial sensor that measures ClO2 in drinking water treatment plants, distribution networks, and other applications that require monitoring ClO2 at the ppb and ppm levels. This instrument uses an amperometric method to measure ClO2 concentration. A membrane allows the selective diffusion of ClO2 molecules to the amperometric sensor. The measurement is compensated for temperature.
Hach 9187 sc 二氧化氯感測器採用安培法(電流法)測量 ClO2 濃度。連續監測飲用水處理廠、配水系統、以及其他需要監測 ppb 和 ppm 等級的水中二氧化氯濃度。量測結果經過溫度補償。
- Selective Membrane Avoids Interference from other species
- Easy Setup and Maintenance 設定簡單, 維護容易
- Compatible with Hach's "Plug and Play" Digital Controllers 與Hach SC系列水質數位控制主機相容
Parameter 分析參數 : Chlorine Dioxide
Measuring Principle 量測方法 : Amperometric/Membrane (electrode, membrane, electrolyte) 安培/膜式(電極、膜、電解質)
Range 量測範圍 : 0 - 2 mg/L ClO2
Accuracy : 5% or ±10 ppb ClO2, whichever is greater
Lower Limit of Detection (LOD) : 0.01 mg/L ClO2
Measuring Interval : Continuous 連續監測
Response Time 反應時間 : 90% in less than 90 seconds
Sample Input : 0.25 " outer diameter
Sample Output : 0.5 " inner diameter
Flow : 14 L/h (200 - 250 mL/min) auto-regulated by flow through cell
Temperature Compensation 溫度補償 : Automatic over sample temperature range
Calibration Method 校正 :
Zero Calibration: Electrically or with ozone-free water
Calibration: Comparison of lab method with process sample
Calibration Interval : 2 months
Maintenance Interval : 6 months for membrane and electrolyte (measurement cell)
Enclosure Rating : IP66 / NEMA 4X
What's included : Hach 9187sc Chlorine Dioxide sensor panel, 4 spare membranes, and Manual.
關鍵字 : 水中二氧化氯 監測儀, 水 二氧化氯 自動分析儀, 水 二氧化氯 感測器, 水 二氧化氯 sensor, ClO2 monitoring, Chlorine Dioxide 線上監測, 二氧化氯 online analyzer
Selective Membrane Avoids Interference from other species
The Hach 9187 sc Amperometric Chlorine Dioxide sensor uses a membrane that is selective for chlorine dioxide species. There are no interferences from bromine, chlorine or hydrogen peroxide. The only potential interference is from ozone, which is rarely present in water treated with chlorine dioxide.
Easy Setup and Maintenance
The all-inclusive 9187 sc ClO2 system comes preassembled on a panel. The membrane system of the sensor means there are no chemicals used for measurement. Maintenance is minimal and two years of typical maintenance items are included with the system.
The all-inclusive 9187 sc ClO2 system comes preassembled on a panel. The membrane system of the sensor means there are no chemicals used for measurement. Maintenance is minimal and two years of typical maintenance items are included with the system.
Compatible with Hach's "Plug and Play" Digital Controllers
The 9187 sc ClO2 sensor is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.
The 9187 sc ClO2 sensor is designed to be used with all Hach sc digital controllers. Set up is fast and easy, and the system is compatible with the full line of Hach digital sensors.