水中總凱氏氮試劑 Simplified TKN (s-TKN™) TNTplus vial test
產品編號:TNT880
Expert Total Kjeldahl Nitrogen test made simple.
專業簡單的水中凱氏總氮分析試劑
Total Kjeldahl Nitrogen TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. 透過Hach分光光度計和總凱氏氮 TNTplus® ,簡化水質分析,每次都獲得準確的結果。
Hach Method 10242 is compliant for EPA wastewater reporting and gives three results for each test - Total Nitrogen, combined nitrate and nitrite, as well as TKN. Unique vial reagent system digests the sample at 120 °C, increasing safety while eliminating ammonia contamination and the need to clean glassware. TNT880 has a range up to 16 mg/L TKN. Hach 測試方法 10242 符合美國 EPA 污水報告要求,每次測試都有三個結果 - 總氮、硝酸鹽和亞硝酸鹽總量以及 TKN。獨特的小試劑瓶可於 120°C 下消解水樣,提高安全性,同時消除氨污染。TNT880 的 TKN 量測範圍高達 16 mg/L。
Parameter 分析參數 : Nitrogen, Simplified Total Kjeldahl
Method Name 分析方法 : Simplified TKN (s-TKN™)
EPA : Equivalent under 40 CFR 136.6
Method Number : 10242
Range 量測範圍 : 0 - 16 mg/L N
Instrument : 使用 Hach 分光光度計 DR3900, DR6000, DR1900, DR2800, DR3800, DR5000 進行分析
關鍵字 : 水中 凱氏氮 檢測, 水 凱氏氮 預製 試劑, 水 凱氏法 分析, Simplified TKN 試劑
專業簡單的水中凱氏總氮分析試劑
Total Kjeldahl Nitrogen TNTplus® chemistry and your Hach spectrophotometer are engineered to simplify water analysis for accurate results, everytime. 透過Hach分光光度計和總凱氏氮 TNTplus® ,簡化水質分析,每次都獲得準確的結果。
Hach Method 10242 is compliant for EPA wastewater reporting and gives three results for each test - Total Nitrogen, combined nitrate and nitrite, as well as TKN. Unique vial reagent system digests the sample at 120 °C, increasing safety while eliminating ammonia contamination and the need to clean glassware. TNT880 has a range up to 16 mg/L TKN. Hach 測試方法 10242 符合美國 EPA 污水報告要求,每次測試都有三個結果 - 總氮、硝酸鹽和亞硝酸鹽總量以及 TKN。獨特的小試劑瓶可於 120°C 下消解水樣,提高安全性,同時消除氨污染。TNT880 的 TKN 量測範圍高達 16 mg/L。
Parameter 分析參數 : Nitrogen, Simplified Total Kjeldahl
Method Name 分析方法 : Simplified TKN (s-TKN™)
EPA : Equivalent under 40 CFR 136.6
Method Number : 10242
Range 量測範圍 : 0 - 16 mg/L N
Instrument : 使用 Hach 分光光度計 DR3900, DR6000, DR1900, DR2800, DR3800, DR5000 進行分析
關鍵字 : 水中 凱氏氮 檢測, 水 凱氏氮 預製 試劑, 水 凱氏法 分析, Simplified TKN 試劑
Easy and safe handling 操作簡單安全
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk. 創新的試劑瓶和試劑設計讓分析測試比粉枕或液體試劑更容易使用,並明顯降低溢出或污染風險。
The innovative vial and reagent delivery makes tests easier to use than powder pillows or liquid reagents and significantly reduces spillage or contamination risk. 創新的試劑瓶和試劑設計讓分析測試比粉枕或液體試劑更容易使用,並明顯降低溢出或污染風險。
No reagent blank necessary 無需試劑空白
The high quality of TNTplus® vials, tight reagent production controls, instrument calibration verification, and high instrument stability all combine to eliminate the need to run reagent blanks—saving you time and money! TNTplus® 試劑瓶的高品質、嚴格的試劑生產控制、校正驗證以及高穩定度,讓您無需進行試劑空白,進而節省時間和金錢
Lot after lot - Be Right 確保準確
Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence. 每個試劑瓶都包含 Truecal™ 校正數據,進而減少結果差異。讓使用者更有信心地進行驗證。
Truecal™ with each vial includes the calibration data for each individual lot, reducing variation in results. This allows you to meet reporting standards and to perform proficiency testing with higher confidence. 每個試劑瓶都包含 Truecal™ 校正數據,進而減少結果差異。讓使用者更有信心地進行驗證。
Automatic method detection 自動方法偵測
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware. 附條碼的試劑瓶可讓分光光度計自動進行方法偵測和測量,因此明顯提高分析速度。儀器平均 10 個讀數,並剔除刮痕、瑕疵或髒污玻璃器皿中的異常值,進而減少誤差
The bar-coded vials allow for automatic method detection and measurement by the spectrophotometer, considerably increasing the speed of analysis. Errors are reduced as instrument averages 10 readings and rejects outliers from scratched, flawed, or dirty glassware. 附條碼的試劑瓶可讓分光光度計自動進行方法偵測和測量,因此明顯提高分析速度。儀器平均 10 個讀數,並剔除刮痕、瑕疵或髒污玻璃器皿中的異常值,進而減少誤差
Documented shelf life and COA 記錄保存期限和 COA
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box. 二維條碼詳細記錄試劑的批號和有效期,並與測量結果一起記錄。若超過有效期限,系統會自動發出警告。批號資訊 (COA) 可於包裝盒上的 RFID 標籤上查看。
New 2D barcode details batch number and expiry date of reagents, which are documented along with the measurement result. An automatic warning is issued if expiry date has passed. Lot specific information (COA) is available on RFID tag on the box. 二維條碼詳細記錄試劑的批號和有效期,並與測量結果一起記錄。若超過有效期限,系統會自動發出警告。批號資訊 (COA) 可於包裝盒上的 RFID 標籤上查看。